How To Set Up Fiber Type Tests On Fluke Versiv 2
Content is AI-generated. Verify critical details with manufacturer-provided resources.
The Versiv2 platform builds on the original Versiv design with enhanced features including integrated Wi-Fi for seamless LinkWare Live connectivity, improved processing power for faster test result management, and compatibility with the latest DSX-8000 module that certifies up to Cat 8 and 2000 MHz cabling systems for 25G and 40G Ethernet applications.
Versiv2 can reduce overall certification costs by up to two-thirds, adding up to 10% to the bottom line of every job. This is achieved through fastest-in-class test times, streamlined workflows that eliminate setup and reporting errors, remote tester management via LinkWare Live, and the ability to track tester calibration status to prevent project delays.
Yes, with the DSX-8000 module, Versiv2 can certify Category 8 and Class I/II cabling up to 2000 MHz for 25GBASE-T and 40GBASE-T applications. The DSX-8000 meets ANSI/TIA-1152-A Level 2G and IEC 61935-1 Level VI accuracy requirements, providing the precision needed for high-performance data center cabling installations.
Versiv2 supports comprehensive fiber testing through interchangeable modules including CertiFiber Pro for Tier 1 OLTS certification, OptiFiber Pro OTDR for Tier 2 extended certification, and fiber inspection capabilities. Quad modules enable testing of both multimode and singlemode fibers without module swaps, significantly improving efficiency on mixed-fiber installations.
Versiv2 excels at managing complex projects through ProjX's ability to store multiple project configurations and LinkWare Live's cloud-based oversight. Project managers can remotely configure test settings and cable IDs for multiple testers across different jobsites, monitor real-time testing progress, and consolidate results automatically for unified reporting, ensuring consistency across large-scale deployments.
Yes, the DSX CableAnalyzer modules on Versiv2 support Transverse Conversion Loss (TCL) and Equal Level Transverse Conversion Transfer Loss (ELTCTL) measurements compliant with IEC 61935-1-1 standards. These balance measurements are critical for determining noise immunity in installations, particularly for industrial networks with high electromagnetic interference concerns.
Versiv2 includes integrated Wi-Fi that meets IEEE 802.11 a/b/g/n standards with dual-band support (2.4 GHz and 5 GHz). This enables direct upload of test results to LinkWare Live from the jobsite, eliminates the need to physically return testers for data download, and allows real-time remote monitoring and configuration of test parameters.
Versiv2 supports 15 languages including English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese (Simplified and Traditional), Korean, Russian, Czech, Polish, Swedish, and Hungarian. This extensive language support makes the platform accessible to global installation teams and ensures proper understanding of test procedures and results worldwide.