RF Preamplifier, 30dB, 100kHz To 8GHz
Electronic Attenuator, 13.6GHz, 1dB Steps
OCXO, Precision Frequency Reference. Aging/Year : 0.35X10E-7 , Temperature Drift : 1X10E-9
EUTRA/LTE FDD Uplink Measurement Application
EUTRA/LTE TDD Uplink Measurement Application
Phase Noise Measurement Application
Modulation Analysis Application For Modulation Analysis Of Analog (AM, FM, PM) Modulated Single Carrier Signals
Vector Signal Analysis Application, For Modulation Analysis On Digital Modulated Single Carrier Signals
3GPP FDD (WCDMA) Ms Measurement Application, Incl. HSUPA And HSUPA+
Cord Power
Qty: 1Hard Drive Removable SATA 2500 FSW with WIN 7
Qty: 1FSW / FSWP MANUALS ON USB DRIVE
Qty: 1Accessory Solid State Drive, 32GB, With Analyzer Firmware; For Exchange Against Standard SSD
OCXO, Precision Frequency Reference. Aging/Year : 0.35X10E-7 , Temperature Drift : 1X10E-9
Security Write Protection Of Solid State Drive
Cord Power
Qty: 1Hard Drive Removable SSD SATA 64 GB
Qty: 2FSW / FSWP MANUALS ON USB DRIVE
Qty: 1RF Preamplifier, 30dB, 100kHz To 8GHz
Electronic Attenuator, 13.6GHz, 1dB Steps
OCXO, Precision Frequency Reference. Aging/Year : 0.35X10E-7 , Temperature Drift : 1X10E-9
Phase Noise Measurement Application
Cord Power
Qty: 1Hard Drive Removable SATA 2500 FSW with WIN 7
Qty: 1FSW / FSWP MANUALS ON USB DRIVE
Qty: 1Ocxo, Precision Frequency Reference. Aging/Year : 0.35x10e-7 , Temperature Drift : 1x10e-9 (Hardware Option)
High Pass Filter, Improved Dynamic Range For Measurement Of Harmonics, Suppression Of Fundamental Signals From 500mhz To 1.5ghz
Rf Preamplifier, 20db, 100khz To 8/13ghz, For R&S?Fsw8 Und R&S?Fsw13, Retrofit In Rohde & Schwarz Service (Hardware Option)
Noise Power Ratio Measurement (Sl)
Phase Noise Measurement Application (Software License)
Emi Measurement Application For Diagnostics Of Rf Interference With Spectrum Analyzers R&S®Fsw (Software License)
Modulation Analysis Application For Modulation Analysis Of Analog (Am, Fm, Pm) Modulated Single Carrier Signals (Software License)
Vector Signal Analysis Application, For Modulation Analysis On Digital Modulated Single Carrier Signals (Software License)
High Pass Filter, Improved Dynamic Range For Measurement Of Harmonics, Suppression Of Fundamental Signals From 500MHz To 1.5GHz
RF Preamplifier, 20dB, 100kHz To 8GHz
OCXO, Precision Frequency Reference. Aging/Year : 0.35X10E-7 , Temperature Drift : 1X10E-9
Noise Power Ratio Measurement
Phase Noise Measurement Application
EMI Measurement Application For Diagnostics Of RF Interference With Spectrum Analyzers R&SFSW
Modulation Analysis Application For Modulation Analysis Of Analog (AM, FM, PM) Modulated Single Carrier Signals
Vector Signal Analysis Application, For Modulation Analysis On Digital Modulated Single Carrier Signals
Cord Power
Qty: 1Hard Drive Removable SATA 2500 FSW with WIN 7
Qty: 1FSW / FSWP MANUALS ON USB DRIVE
Qty: 1Electronic Attenuator, 13.6GHz, 1dB Steps
Extension To 320MHz Signal Analysis Bandwidth
OCXO, Precision Frequency Reference. Aging/Year : 0.35X10E-7 , Temperature Drift : 1X10E-9
Analog Base Band Inputs, Analysis Bandwidth 40MHz
80MHz Analysis Bandwidth For Analog Base Band Inputs
Resolution Bandwidth >10MHz, 20MHz And 50MHz Additionally
GSM Measurement Application, GSM, EDGE, EDGE Evolution And VAMOS
160MHz Real-Time Spectrum Analyzer, R&SFSW-B160/B320 Required
3GPP TDD (TD-SCDMA) UE Measurement Application
Power Amplifier And Envelope Tracking Measurement Application
Phase Noise Measurement Application
3GPP FDD (WCDMA) Ms Measurement Application, Incl. HSUPA And HSUPA+
CDMA2000 Ms Measurement Application
1XEV-DO Ms Measurement Application
RF Preamplifier, 20dB, 100kHz To 8GHz
Cord Power
Qty: 1Hard Drive Removable SATA 2500 FSW with WIN 7
Qty: 1Cable Semi-Rigid Loopback BNC(m)-BNC(m)
Qty: 1FSW / FSWP MANUALS ON USB DRIVE
Qty: 1RF Preamplifier, 20dB, 100kHz To 8GHz
OCXO, Precision Frequency Reference. Aging/Year : 0.35X10E-7 , Temperature Drift : 1X10E-9
Extension To 80MHz Signal Analysis Bandwidth, Includes Microwave Preselector Bypass
Noise Figure Measurement Application, Noise Source Required
Phase Noise Measurement Application
Pulse Measurement Application
Cord Power
Qty: 1FSW / FSWP MANUALS ON USB DRIVE
Qty: 1Extension To 320MHz Signal Analysis Bandwidth
DOCSIS 3.1 OFDM Downstream Measurement Application
Vector Signal Analysis Application, For Modulation Analysis On Digital Modulated Single Carrier Signals
DOCSIS 3.1 OFDMA Upstream Measurement Application
Noise Power Ratio Measurement
Cord Power
Qty: 1FSW / FSWP MANUALS ON USB DRIVE
Qty: 1RF Preamplifier, 20dB, 100kHz To 8GHz
Extension To 512 MHz Signal Analysis Bandwidth Including 200 MHz IF Filter
Cord Power
Qty: 1FSW / FSWP MANUALS ON USB DRIVE
Qty: 1RF Preamplifier, 20dB, 100kHz To 8GHz
Cord Power
Qty: 1FSW / FSWP MANUALS ON USB DRIVE
Qty: 1FSW / FSWP MANUALS ON USB DRIVE
Qty: 1FSW / FSWP MANUALS ON USB DRIVE
Qty: 1FSW / FSWP MANUALS ON USB DRIVE
Qty: 1RF preamplifier, 30dB, 100kHz to 8/13GHz, for R&S®FSW8 und R&S®FSW13, retrofit in Rohde & Schwarz service (hardware option)
Extension to 28MHz signal analysis bandwidth, includes microwave preselector bypass
Noise figure measurement application, noise source required, preamplifier
Phase noise measurement application (software license)
Vector signal analysis application, for modulation analysis on digital modulated single carrier signals (software license)
Content is AI-generated. Verify critical details with manufacturer-provided resources.
The Rohde & Schwarz FSW8 signal and spectrum analyzer covers a frequency range from 2 Hz to 8 GHz when DC coupled, or 10 MHz to 8 GHz when AC coupled. The instrument provides exceptional frequency resolution down to 0.01 Hz with frequency readout accuracy determined by the reference accuracy, resolution bandwidth, and span settings. This wide frequency coverage makes it suitable for comprehensive RF and microwave signal analysis across a broad range of applications.
The FSW8 delivers excellent sensitivity with displayed average noise levels of -145 dBm (typical -150 dBm) from 9 kHz to 1 MHz, improving to -150 dBm (typical -154 dBm) from 1 MHz to 1 GHz with RF attenuation at 0 dB and no preamplifier. With the optional RF preamplifier engaged at 30 dB gain, the noise floor reaches -163 dBm (typical -166 dBm) from 50 MHz to 150 MHz and -166 dBm (typical -169 dBm) from 150 MHz to 8 GHz, providing outstanding measurement sensitivity for low-level signal analysis.
The R&S FSW8 is designed to safely handle significant input power with a maximum CW RF power of 30 dBm (1 W) when RF attenuation is set to 10 dB or greater. At 0 dB attenuation, the maximum input is 20 dBm. The analyzer also tolerates up to 50 V DC voltage on AC coupled inputs and features pulse spectral density handling of 97 dB uV/MHz at 0 dB attenuation with the preamplifier off, protecting the sensitive front-end circuitry during diverse measurement scenarios.
The FSW8 exhibits outstanding phase noise characteristics with SSB phase noise at 1000 MHz carrier frequency reaching -109 dBc (1 Hz) at 100 Hz offset and better than -127 dBc (1 Hz), typical -132 dBc at 1 kHz offset without the OCXO option. With the optional R&S FSW-B4 OCXO precision frequency reference, close-in phase noise improves significantly to -95 dBc (1 Hz), typical -100 dBc at 10 Hz offset. These specifications ensure accurate measurements of low phase noise sources and high-quality oscillators.
The FSW8 offers flexible resolution bandwidth settings from 1 Hz to 10 MHz in standard 1/2/3/5 sequence, plus 3.9 kHz and 6.25 kHz bandwidths. With the optional R&S FSW-B8 option, additional bandwidths of 20 MHz, 50 MHz, and 80 MHz become available. Channel filters provide bandwidths from 100 Hz to 10 MHz with root raised cosine filter shapes, offering shape factors better than 5:1 for sweep and FFT filters and less than 2:1 for channel filters with nominal bandwidth accuracy under 3 percent.
The R&S FSW8 demonstrates excellent linearity with third-order intercept (TOI) performance exceeding 25 dBm (typical 30 dBm) from 10 MHz to 1 GHz with RF attenuation at 0 dB, two-tone level at -15 dBm each, and preamplifier off. From 1 GHz to 3 GHz, the TOI exceeds 20 dBm (typical 25 dBm), and from 3 GHz to 8 GHz it exceeds 17 dBm (typical 20 dBm). This high dynamic range capability allows simultaneous measurement of strong and weak signals without significant intermodulation distortion.
The FSW8 offers versatile sweep time capabilities ranging from 3 microseconds to 16000 seconds for spans of 10 Hz or greater, with sweep time accuracy of approximately 3 percent nominal. For zero span measurements, the sweep time range extends from 1 microsecond to 16000 seconds with 0.1 percent nominal accuracy. The number of sweep points is configurable from 101 to 100001 points with a default of 1001 points, allowing users to balance measurement speed against frequency resolution requirements.
The standard FSW8 provides 10 MHz equalized signal analysis bandwidth. This can be expanded through optional upgrades to 28 MHz, 40 MHz, 80 MHz, 160 MHz, 320 MHz, and 512 MHz. The R&S FSW-B1200 option extends this to 1200 MHz. Note that the FSW8 does not have a YIG preselector since its frequency range is limited to 8 GHz, and the R&S FSW-B2000 2 GHz external bandwidth option is not available for the FSW8 or FSW13 models.