2-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees
Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cable RF Front-Rear Panel Jumper SMA(m) - SMA(m)
Qty: 12Power cord Right Angle
Qty: 1Cover Impact Rear Phantom Gray
Qty: 1Cover Front Impact Gray
Qty: 1USB Drive with Software and Manuals
Qty: 1Cable Guard
Qty: 2Handle Front Die Cast Gray
Qty: 150 ohm SMA Terminator, male
Qty: 22-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees
Frequency-offset measurements
Node-locked perpetual license
Scalar mixer/converter measurements
Node-locked perpetual license
Keysight Software Support While On Rent
Keysight Software Support While On Rent
Handle Front Die Cast Gray
Qty: 1Power cord Right Angle
Qty: 1Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cable RF Front-Rear Panel Jumper SMA(m) - SMA(m)
Qty: 6Cable Guard
Qty: 2Cover Front Impact Gray
Qty: 1Cover Impact Rear Phantom Gray
Qty: 1USB Drive with Software and Manuals
Qty: 150 ohm SMA Terminator, male
Qty: 22-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees
Synthesizer version 7.0
Handle Front Die Cast Gray
Qty: 1Power cord Right Angle
Qty: 1Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cable RF Front-Rear Panel Jumper SMA(m) - SMA(m)
Qty: 6Cable Guard
Qty: 2Cover Front Impact Gray
Qty: 1Cover Impact Rear Phantom Gray
Qty: 1USB Drive with Software and Manuals
Qty: 150 ohm SMA Terminator, male
Qty: 2Add pulse modulator to internal 1st source
2-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees
Handle Front Die Cast Gray
Qty: 1Power cord Right Angle
Qty: 1Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cable RF Front-Rear Panel Jumper SMA(m) - SMA(m)
Qty: 6Cable Guard
Qty: 2Cover Front Impact Gray
Qty: 1Cover Impact Rear Phantom Gray
Qty: 150 ohm SMA Terminator, male
Qty: 2USB Drive with Software and Manuals
Qty: 1Keysight Technologies PNA-B Spec Sheet
Keysight Technologies PNA Configuration Guide
Keysight Technologies PNA Configuration Guide
Content is AI-generated. Verify critical details with manufacturer-provided resources.
The Keysight N5225B is a 2-port PNA microwave network analyzer covering 900 Hz to 50 GHz, configured with Option 219. This option includes front-panel access loops, source and receiver attenuators for extended power range, and bias tees. The N5225B features 50 ohm, ruggedized 2.4 mm male test port connectors, a 12.1-inch LCD touch screen display, a solid-state drive, and USB interfaces.
With Option 219, the N5225B achieves excellent system dynamic range at 10 Hz IF bandwidth. The extended dynamic range at the direct receiver access input provides additional measurement headroom. Option 219 is a 2-port configuration with Ports 1 and 2. Consult the N5225B data sheet for specific dynamic range values across frequency bands.
The N5225B is a PNA series analyzer, while the N5245B is a PNA-X. Both cover 900 Hz to 50 GHz with 2.4 mm test port connectors. The PNA-X exclusively supports Option 029 (low-noise receiver for noise figure), nonlinear vector network analysis (NVNA/X-parameters), a third source option (XSB), and active hot parameters. The PNA series provides a cost-effective solution for high-performance S-parameter and mixer/converter measurements.
On the N5225B with Option 219, source and receiver attenuators are included for extended power range. The bias tees are connected directly to the test port couplers, which limits the maximum power rating on the pair to +30 dBm. Consult the N5225B data sheet for specific attenuator step sizes and maximum attenuation values for Option 219.
The N5225B PNA supports S-parameter measurements, time domain analysis (S93010B), enhanced time domain with TDR (S93011B), automatic fixture removal (S93007B), gain compression (S93086B), intermodulation distortion (S93087B), scalar and vector mixer/converter measurements (S93082B/S93083B), noise figure measurements (S93029B using standard receivers), pulsed-RF measurements, and spectrum analysis up to 50 GHz (S930905B).
Yes, the N5225B PNA supports low-frequency extension (LFE) through Option 205 (2-port with LFE) and Option 220 (2-port with attenuators, bias tees, and LFE). With LFE enabled, measurements from 500 Hz to 100 MHz use LFE hardware. The typical system dynamic range with LFE starts at 105 dB at 500 Hz to 900 Hz and reaches 127 dB at 1 to 5 MHz.
The N5225B supports the 85056A and 85056D mechanical calibration kits and the N4693A and N4693D 2-port electronic calibration modules, all designed for 2.4 mm connectors. Keysight provides a free Uncertainty Calculator to generate specification curves for specific calibration setups. Built-in performance test software (S93898B) is available for self-maintainers requiring standard compliant calibration.
Yes, the N5225B PNA supports time domain analysis through the S93010B software application, which converts frequency-domain S-parameter data into the time domain for identifying discontinuities and impedance variations along a transmission path. Enhanced time domain analysis with TDR capability is available through S93011B, which includes all features of S93010B plus time domain reflectometry. The N5225B also supports automatic fixture removal (S93007B), which mathematically de-embeds test fixture effects from the measurement to establish accurate reference planes at the device under test.