4-port with second source
Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Power cord Right Angle
Qty: 1Cover Front
Qty: 1Cover Rear
Qty: 1USB Drive with Software and Manuals
Qty: 1Handle Front Die Cast Gray
Qty: 150 ohm SMA Terminator, male
Qty: 2Add IF inputs
4-port with second source
Scalar mixer/converter measurements
Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Power cord Right Angle
Qty: 1Cover Front
Qty: 1Cover Rear
Qty: 1USB Drive with Software and Manuals
Qty: 1Handle Front Die Cast Gray
Qty: 150 ohm SMA Terminator, male
Qty: 24-port with second source
Time Domain
Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Power cord Right Angle
Qty: 1Keyboard USB
Qty: 1Mouse Optical
Qty: 1Cover Front
Qty: 1Cover Rear
Qty: 1USB Drive with Software and Manuals
Qty: 1Handle Front Die Cast Gray
Qty: 150 ohm SMA Terminator, male
Qty: 24-port with second source
Synthesizer and reference assembly, version 7 DDS, dual-source
Handle Front Die Cast Gray
Qty: 1Power cord Right Angle
Qty: 1Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cover Front
Qty: 1Cover Rear
Qty: 1USB Drive with Software and Manuals
Qty: 150 ohm SMA Terminator, male
Qty: 2Add pulse modulator to internal 1st source
Add pulse modulator to internal 2nd source
4-port with second source
Synthesizer and reference assembly, version 7 DDS, dual-source
Handle Front Die Cast Gray
Qty: 1Power cord Right Angle
Qty: 1Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cover Front
Qty: 1Cover Rear
Qty: 1USB Drive with Software and Manuals
Qty: 1PNA Core Software to 26.5 GHz
Core Software node-locked perpetual license
Core software updates and enhancements, node-locked - 1 year
4-port with second source
Time-domain analysis
Node-locked perpetual license
Keysight Software Support While On Rent
Handle Front Die Cast Gray
Qty: 1Power cord Right Angle
Qty: 1Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cover Front
Qty: 1Cover Rear
Qty: 1USB Drive with Software and Manuals
Qty: 150 ohm SMA Terminator, male
Qty: 2Add IF inputs
4-port with second source
Synthesizer version 7
Add pulse modulator to internal 1st source
Add pulse modulator to internal 2nd source
Handle Front Die Cast Gray
Qty: 1Power cord Right Angle
Qty: 1Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cover Front
Qty: 1Cover Rear
Qty: 1USB Drive with Software and Manuals
Qty: 150 ohm SMA Terminator, male
Qty: 2Add pulse modulator to internal 1st source
4-port with second source
Handle Front Die Cast Gray
Qty: 1Power cord Right Angle
Qty: 1Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cover Front
Qty: 1Cover Rear
Qty: 150 ohm SMA Terminator, male
Qty: 2USB Drive with Software and Manuals
Qty: 1Keysight Technologies PNA B Family Config Guide
Keysight Technologies PNA Configuration Guide
Content is AI-generated. Verify critical details with manufacturer-provided resources.
The Keysight N5222B operates from 900 Hz/10 MHz to 26.5 GHz, making it suitable for microwave device characterization and RF component testing. The analyzer provides broad frequency coverage for measuring S-parameters of amplifiers, filters, mixers, and other passive and active components across this range.
The N5222B with Option 400 is a 4-port base model configuration with a standard test set. This option provides four test ports for multiport device measurements without additional extended power range features or bias-tees. The 4-port configuration enables full 4-port S-parameter measurements and supports comprehensive multiport component characterization.
The N5222B PNA network analyzer features precision connectors on the test ports that provide reliable performance across the full 26.5 GHz frequency range. The PNA family supports various calibration kits for 1.85 mm, 2.4 mm, 3.5 mm/SMA, and Type-N connector interfaces.
Yes, the N5222B supports mixer and converter measurements with the appropriate application software. Software options S93082B for scalar mixer/converter measurements and S93083B for vector and scalar mixer/converter measurements enable frequency-offset testing and comprehensive mixer characterization using the analyzer's configurable test set architecture.
The N5222B supports both mechanical and electronic calibration methods. Mechanical calibration can be performed using standards such as the 85056A calibration kit for devices with various connector types. Electronic calibration modules provide faster, more repeatable calibration with reduced operator variation, and the analyzer includes ISO 17025, commercial UK6, and ANSI Z540 compliant calibration certification options.
Yes, the N5222B supports time domain analysis through software option S93010B, which provides basic time domain functionality. For enhanced capabilities, option S93011B adds time domain reflectometry with all the features of S93010B, enabling detailed fault location and impedance discontinuity analysis in transmission lines and cables.
The N5222B with Option 400 provides a system dynamic range of 127 dB from 1 GHz to 26.5 GHz at 10 Hz IF bandwidth. This wide dynamic range enables accurate measurements of devices with high insertion loss or low reflection coefficients, critical for filter, attenuator, and low-loss component testing.
Yes, the N5222B can perform noise figure measurements when equipped with the S93029B application software. This software enables noise figure and noise power measurements using the standard receivers or, for enhanced sensitivity, can work with optional low-noise receiver hardware for improved measurement accuracy at lower noise levels.