2-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees
Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cable RF Front-Rear Panel Jumper SMA(m) - SMA(m)
Qty: 6Power cord Right Angle
Qty: 1Cover Front
Qty: 1Cover Rear
Qty: 1USB Drive with Software and Manuals
Qty: 1Cable Guard
Qty: 2Handle Front Die Cast Gray
Qty: 150 ohm SMA Terminator, male
Qty: 22-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees
Node-locked perpetual license
Vector and Scalar Mixer/Converter Measurements
Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cable RF Front-Rear Panel Jumper SMA(m) - SMA(m)
Qty: 6Power cord Right Angle
Qty: 1Cover Front
Qty: 1Cover Rear
Qty: 1USB Drive with Software and Manuals
Qty: 1Cable Guard
Qty: 2Handle Front Die Cast Gray
Qty: 12-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees
Frequency-offset measurements
Vector and Scalar Mixer/Converter Measurements
Handle Front Die Cast Gray
Qty: 1Power cord Right Angle
Qty: 1Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cable RF Front-Rear Panel Jumper SMA(m) - SMA(m)
Qty: 6Cable Guard
Qty: 2Cover Front
Qty: 1Cover Rear
Qty: 1USB Drive with Software and Manuals
Qty: 1Add IF inputs
2-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees
Handle Front Die Cast Gray
Qty: 1Power cord Right Angle
Qty: 1Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cable RF Front-Rear Panel Jumper SMA(m) - SMA(m)
Qty: 6Cable Guard
Qty: 2Cover Front
Qty: 1Cover Rear
Qty: 1USB Drive with Software and Manuals
Qty: 150 ohm SMA Terminator, male
Qty: 2Add pulse modulator to internal 1st source
2-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees
Synthesizer 7.0
Handle Front Die Cast Gray
Qty: 1Power cord Right Angle
Qty: 1Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cable RF Front-Rear Panel Jumper SMA(m) - SMA(m)
Qty: 6Cable Guard
Qty: 2Cover Front
Qty: 1Cover Rear
Qty: 1USB Drive with Software and Manuals
Qty: 150 ohm SMA Terminator, male
Qty: 22-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees
Synthesizer 7.0
Handle Front Die Cast Gray
Qty: 1Power cord Right Angle
Qty: 1Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cable RF Front-Rear Panel Jumper SMA(m) - SMA(m)
Qty: 6Cable Guard
Qty: 2Cover Front
Qty: 1Cover Rear
Qty: 1USB Drive with Software and Manuals
Qty: 150 ohm SMA Terminator, male
Qty: 2Keysight Technologies N5222B Spec Sheet
Keysight Technologies N52xxB Configuration Guide
Keysight Technologies PNA Configuration Guide
Content is AI-generated. Verify critical details with manufacturer-provided resources.
The N5222B with Option 219 adds front-panel jumpers, R1 receiver switch, source and receiver attenuators for extended power range, and bias-tees. The bias-tees enable DC bias injection for active device testing such as amplifiers and mixers, while the attenuators extend the power sweep range and protect receivers from high input levels.
The integrated bias-tees in Option 219 allow simultaneous application of DC power and RF signals to the device under test without external bias equipment. This is essential for characterizing active components like transistors, amplifiers, and frequency converters that require DC operating points while performing S-parameter measurements across the full 10 MHz to 26.5 GHz range.
Option 219 includes both source and receiver attenuators that extend the usable power range of the analyzer. The minimum settable power reaches -95 dBm compared to -30 dBm on the base Option 200 model, and the source attenuators allow precise low-power testing for sensitive device characterization while receiver attenuators prevent compression from high-power signals.
Front-panel jumpers provide direct access to internal signal paths including source outputs, receiver inputs, and reference receivers. This enables advanced measurement configurations such as external mixing, amplifier insertion for extended dynamic range, external filtering, and custom test setups that require access to intermediate signal paths not available on standard test ports.
The N5222B with Option 219 achieves specified system dynamic range of 127 dB from 500 MHz to 16 GHz and 124 dB from 16 to 20 GHz. From 20 to 24 GHz the dynamic range is 121 dB, and from 24 to 26.5 GHz it is 109 dB. Typical performance exceeds these specifications, reaching 138 dB from 500 MHz to 2 GHz.
After full 2-port calibration with the 85052B mechanical cal kit, the N5222B-219 achieves directivity of 44 dB and source match of 31 dB from 2 to 26.5 GHz. Reflection tracking magnitude is ±0.006 dB with ±0.040 degrees phase, while transmission tracking magnitude ranges from ±0.091 dB at lower frequencies to ±0.119 dB from 20 to 26.5 GHz.
Option 219 is optimized for active device characterization including amplifier gain compression, mixer conversion loss, and frequency converter measurements. The combination of bias-tees for DC biasing, extended power range via source and receiver attenuators, and front-panel jumper access makes it ideal for semiconductor validation and nonlinear component testing environments.
The preset (nominal) power for Option 219 is -5 dBm, compared to 0 dBm on the base Option 200 model. This lower preset power is a safety feature that accounts for the receiver attenuators and bias-tees in the signal path, helping to protect sensitive devices under test from excessive power levels during initial setup.