2-port, base hardware configuration
Cord Power
Qty: 1Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cover Front
Qty: 1Cover Rear
Qty: 1USB Drive with Software and Manuals
Qty: 1Handle Front Die Cast Gray
Qty: 150 ohm SMA Terminator, male
Qty: 22-port, base hardware configuration
Time domain analysis, fixed perpetual license
Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Power cord Right Angle
Qty: 1Cover Front
Qty: 1Cover Rear
Qty: 1USB Drive with Software and Manuals
Qty: 1Handle Front Die Cast Gray
Qty: 150 ohm SMA Terminator, male
Qty: 22-port, base hardware configuration
Time Domain
Node-locked perpetual license
Keysight Software Support While On Rent
Cord Power
Qty: 1Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cover Front
Qty: 1Cover Rear
Qty: 1USB Drive with Software and Manuals
Qty: 1Handle Front Die Cast Gray
Qty: 1Add pulse modulator to internal 1st source
2-port, base hardware configuration
Cord Power
Qty: 1Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cover Front
Qty: 1Cover Rear
Qty: 1USB Drive with Software and Manuals
Qty: 1Handle Front Die Cast Gray
Qty: 150 ohm SMA Terminator, male
Qty: 22-port, base hardware configuration
Synthesizer and reference assembly, version 7 DDS, dual-source
Cord Power
Qty: 1Handle Front Die Cast Gray
Qty: 1Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cover Front
Qty: 1Cover Rear
Qty: 1USB Drive with Software and Manuals
Qty: 150 ohm SMA Terminator, male
Qty: 2Add pulse modulator to internal 1st source
2-port, base hardware configuration
Synthesizer and reference assembly, version 7 DDS, dual-source
Cord Power
Qty: 1Handle Front Die Cast Gray
Qty: 1Wrench Torque 8 in/lb 20 mm Open End
Qty: 1Cover Front
Qty: 1Cover Rear
Qty: 1USB Drive with Software and Manuals
Qty: 150 ohm SMA Terminator, male
Qty: 22-port, base hardware configuration
Time domain analysis, fixed perpetual license
Synthesizer 7 upgrade
Keysight Technologies N52xxB Configuration Guide
Keysight Technologies PNA Configuration Guide
Content is AI-generated. Verify critical details with manufacturer-provided resources.
The N5222B with Option 200 operates from 10 MHz to 26.5 GHz as a 2-port base model in the PNA B-series family. The start frequency can be extended down to 900 Hz when paired with the optional low-frequency extension hardware (Option 205) on compatible configurations.
The N5222B offers several 2-port configurations: Option 201 adds front-panel jumpers and R1 receiver switch, Option 205 adds front-panel jumpers with low-frequency extension (LFE) hardware, Option 217 adds source and receiver attenuators for extended power range, and Option 219 adds all of Option 217 plus bias-tees. Four-port models are also available as Options 400, 401, 417, and 419.
The N5222B achieves typical receiver dynamic range of 130 dB from 500 MHz to 2 GHz and 131 dB from 2 to 13.5 GHz, calculated as the 0.1 dB compression point at the test port minus the typical noise floor. At higher frequencies the receiver dynamic range is 132 dB from 13.5 to 20 GHz, 128 dB from 20 to 24 GHz, and 126 dB from 24 to 26.5 GHz.
Trace noise specifications define measurement repeatability and are frequency-dependent. The analyzer provides both magnitude trace noise in dB rms and phase trace noise in degrees rms, with performance varying based on IF bandwidth settings. Narrower IF bandwidths and averaging improve trace noise at the expense of measurement speed.
The N5222B-200 provides a specified power sweep range of 38 dB from 50 MHz to 16 GHz at both Port 1 and Port 2. From 20 to 24 GHz the range is 35 dB at Port 2, and from 24 to 26.5 GHz it drops to 30 dB at Port 2. Typical performance extends these ranges significantly, reaching 47 to 49 dB in many frequency bands.
Yes, with Option 205 the N5222B adds low-frequency extension (LFE) hardware that enables measurements down to 900 Hz (or 500 Hz typical). When LFE is enabled, measurements from 500 Hz to 100 MHz use LFE hardware, while all measurements above 100 MHz use standard hardware regardless of the LFE setting.
Uncorrected (raw) specifications show instrument performance before calibration. The N5222B provides specified raw directivity of 24 dB from 50 MHz to 3.2 GHz, source match of 18 dB, and load match of 17 dB in that same range. These raw error terms affect calibration stability and determine how well a calibration holds over time and temperature.
All specifications apply over a 25 degrees Celsius ±5 degrees range after 90 minutes warm-up time. Corrected system performance specifications require environmental temperature of 23 degrees ±3 degrees with less than 1 degree deviation from calibration temperature to maintain warranted measurement uncertainty levels.